Studer A-827 Cat 1 Errors


Revised: Greg Loskorn 3/27/99

Cat 1 :
Fatal - Continued operation is impossible. Machine power must be
switched off for at least 10 sec. If the error reappears, it should be
remedied. If error doesn't reappear, all should be O.K.
--------------------------------------
Cat 1 :
Fatal
ERR: SUPPLY
VOLTAGE
Cause: Supply voltage(s) missing.
Check fuses.
Check voltages on:
1.820.871 (+-15v) or 1.820.873 (+-15v)
1.820.872 (+-5.6v, +-27v, +24v)
--------------------------------------
Cat 1 :
Fatal
ERR: MASTER DATA
LOST
Cause: Tape tension data lost.
Cycle power to load default params.
Check MASTER MPU 1.820.784 battery.
Check PSU voltages.
--------------------------------------
Cat 1 :
Fatal
ERR: SPOOLING MOTOR
SERVO HARDWARE
Cause: Error in the analog spooling motor control circuit or missing or
open current feedback.
Check voltages and signals:
Move sensor 1.820.770
Spooling motor drive amp 1.820.875
Tape tension sensors 1.820.772 or .877
=========================