Studer 827 Category 2 Errors
Read The Disclaimer E-Mail A Link To This Page To A Friend!




Go Back To The PalmPilot Scripts Page
by Greg Loskorn

Studer A-827 Cat 2 Errors


Revised: Greg Loskorn 3/27/99

Cat 2 :
Non-fatal - Operation can continue. Error messages remain when the
error has disappeared. Messages must be acknowledged by pressing STORE. If
the error persists, the machine can still be operated.
--------------------------------------
Cat 2 :
Non-fatal
ERR: POWER
DROP OUT
Cause: Transient line voltage failure >100ms.
Acknowledge with STORE.
--------------------------------------
Cat 2 :
Non-fatal
ERR: MOVE-SENSOR
HARDWARE
Cause: MOVE SENSOR PCB 1.820.770 or MOTOR TACHO PCB 1.820.771 defective or
too many tape move direction changes detected.
Repair, replace, or re-align (Sections 3.3.3 and 3.3.11)
--------------------------------------
Cat 2 :
Non-fatal
ERR: SPOOLING MOTOR
TACHO RIGHT/LEFT
Cause: Right/left spooling tacho motor signals too many direction changes
or supplies no signal.
Repair, replace, or re-align (if possible).
=========================