Studer A-827 Cat 2 ErrorsRevised: Greg Loskorn 3/27/99 Cat 2 : Non-fatal - Operation can continue. Error messages remain when the error has disappeared. Messages must be acknowledged by pressing STORE. If the error persists, the machine can still be operated. -------------------------------------- Cat 2 : Non-fatal ERR: POWER DROP OUT Cause: Transient line voltage failure >100ms. Acknowledge with STORE. -------------------------------------- Cat 2 : Non-fatal ERR: MOVE-SENSOR HARDWARE Cause: MOVE SENSOR PCB 1.820.770 or MOTOR TACHO PCB 1.820.771 defective or too many tape move direction changes detected. Repair, replace, or re-align (Sections 3.3.3 and 3.3.11) -------------------------------------- Cat 2 : Non-fatal ERR: SPOOLING MOTOR TACHO RIGHT/LEFT Cause: Right/left spooling tacho motor signals too many direction changes or supplies no signal. Repair, replace, or re-align (if possible). ========================= |
|
|