Studer A-827 Cat 3 Errors (Page 1)


Revised: Greg Loskorn 3/27/99

Cat 3 :
Non-fatal -
Operation can continue. Error messages disappear when
the error has disappeared. Messages can be acknowledged by pressing STORE,
even though error may still persist.
--------------------------------------
Cat 3 :
Non-fatal
ERR: MOTOR SUPPLY
VOLTAGE LOW
Cause: Failure of motor supply voltage
Wait 10 sec. If error persists, check fuses F1 & F2 (next to power switch).
Repair or replace SPOOLING MOTOR DRIVE AMPLIFIER 1.820.875
--------------------------------------
Cat 3 :
Non-fatal
ERR: NO COMMUNICAT.
MASTER-TAPE DECK
Cause: No response to the status inquiry
Software on the MASTER MPU 1.820.784 not compatible with the
TAPE DECK MPU1.820.781
Replace or repair the MASTER SERIAL INTERFACE 1.820.753 and/or the TAPE
DECK SERIAL INTERFACE 1.820.763
--------------------------------------
Cat 3 : Non-fatal
ERR: NO COMMUNICAT.
MASTER-AUDIO
Cause: No response to the status inquiry
Software on the MASTER MPU 1.820.784 not compatible with the AUDIO MPU
1.820.782 or 1.827.788
Replace or repair the MASTER AUDIO INTERFACE 1.820.756 and/or the
COMMUNICATIONS CONTROLLER 1.820.718
Replace the software EPROMs (IC 15,16,18) on each MPU.
--------------------------------------
Cat 3 :
Non-fatal
ERR: AUDIO DATA
LOST
Cause: Audio data lost
Cycle power to load default params
Check the battery on the AUDIO MPU 1.820.782
Re-align from tape
--------------------------------------
Cat 3 : Non-fatal
ERR: TACHO SENSOR
Cause: No output from one of the three tacho sensors: SPOOLING MOTORS
1.820.771, or MOVE SENSOR 1.820.770; the three senses of rotation do not
agree, or no tacho signal from the spooling motor
with a motor current of >4A.
Check the flat cable connector to the sensors.
Check the sensors and replace or repair them, if necessary.
Check that the spindles and the tacho roller rotate without binding.
--------------------------------------
Cat 3 :
Non-fatal
ERR: TAPE TENSION
CONTROL
Cause: Deviation of the tpe tension from the reference too large for
approx. 1sec.
Clean the tape guide rollers.
Check whether the friction of the tape transport and the spindles is too high.
Check the tape tensions.
--------------------------------------
Cat 3 :
Non-fatal
ERR: NO COMMUNICAT.
CAPSTAN-TAPE DECK
Cause: No data communication via the parallel interface of the CAPSTAN
INTERFACE 1.820.727
Replace or repair the CAPSTAN INTERFACE.
--------------------------------------
Cat 3 : Non-fatal
ERR: INCORRECT
RADIUS MEASUREMENT
Cause: The calculated radius of the tape pancake is outside the admissible
limits, or tacho sensor defective.
PLAY tape for a few seconds. This message normally disappears as soon as a
sufficient number of tacho pulses are available for calculating the pancake
radius. Check tacho sensor and replace it if necessary.
Set the 'MAX REEL SIZE' to 14".
--------------------------------------
Cat 3 :
Non-fatal
ERR: REMOTE SHUTTLE
VALUE HARDWARE
Cause: Incorrect values were supplied by the SHUTTLE pot during the init phase.
The SHUTTLE wheel should not be operated during the init phase.
Re-adjust the SHUTTLE pot (Section 3.3.12)
--------------------------------------
Cat 3 :
Non-fatal
ERR: PINCH ROLLER
SLIPPING
Cause: The pinch roller slip is too high; the capstan speed does not agree
with the tape speed.
Clean the pinch roller and capstan shaft; replace the pinch roller if
necessary.
Adjust the pinching force to the correct value.
=========================